3-Phase AC/DC Standard Power & Indicating Meter

Capable of testing all types of AC ammeter, AC voltmeter, DC ammeter, DC voltmeter, power meter, AC phase meter, power factor meter and frequency meter.
Acts as 3-phase AC standard source, as 3-phase DC standard source, 3-phase power standard source and 3-phase harmonic standard source.

These built-ins are voltmeter, ammeter, phase meter, power meter, power factor meter, harmonic meter. All meters above are in high precision (0.05 class)

Realize closed loop control on current outputs, voltage output, power output, phase output and harmonic output guaranteeing its low drift and its steady annual stability.

2-19 times harmonic output, standard output in 0.1 class; while 20-31 times are those standard outputs in 0.2 class

Working mode: Meter Calibration Output Mode, Standard Source Output Mode

Built-in RS232 port allows software upgrade and calibrated date transfer without opening up the external box of the equipment.

Software possesses self-calibration function, users can calibrate all kinds of electric measurement parameters values without opening up the external box of the equipment.

Automatic Faults Test of software figures out where faults occur in the relay test set.

Displaying popup Menu in English version by large TFT LCD, allows multi-operation modes.
(1) Rotary encoder operation
(2) Slight-touch style keyboard?
(3) Operation under PC Windows System

Save Volume reaches up to 1000 calibrated data

Calibrated data can be revised to meet due value by software, calibration report and calibrated data can get printed by software as well.

Remark:

Voltage (AC) Output/Measure
Shift

10V/30V/100V/300V/750V Auto switch
Adjusting range

0 ... 120%
Min Adjusting Unit

Shift x 0.01%
Resolution

Shift x 0.01%
Accuracy

0.05%RG (RG abbr. range)
Stability

0.01%/1min
Current (AC) Output/Measure
Shift

100mA/1A/5A/10A/25A Auto switch
Adjusting range

0 ... 120%
Min Adjusting Unit

Shift x 0.01%
Resolution

Shift x 0.01%
Accuracy

0.05%RG
Stability

0.01%/1min
Power Output/Measure
Min Adjusting Unit

Shift x 0.01%
Resolution

Shift x 0.01%
Accuracy

0.05%RG (F>0.5)
Stability

0.01%/1min
Frequency Output/Measure
Range

45.000...65.000Hz
Min Adjusting Unit

0.001Hz
Accuracy

0.01%RD
Phase Output/Measure
Range

0.00 ... 359.99
Min Adjusting Unit

0.01
Resolution

0.01
Accuracy

0.05
Power factor Output/Measure
Output range

-1 ... 0 ... +1
Min Adjusting Unit

0.0001
Accuracy

0.0005
Harmonic Output/Measure
Set range

2 ... 31 times
Content

Voltage, Current?30%( compared with Fundamental Wave)
Harmonic output accuracy

0.1%(2 ... 19 times, compared with Fundamental Wave)
Resolution

0.2%(20 ... 31 times, compared with Fundamental Wave)
Harmonic Phase

0.00 ... 359.99
Output Voltage and Current distortion
<0.2%(non capacitance load)
Max AC Output Load
Voltage 25VA, Current 25VA
Voltage (DC) Output/Measure
Shift

100mV/1V/10V/30V/100V/300V/750V
Adjusting range

0 ... 120%, 0 ... 110% at shift 750V
Min Adjusting Unit

Shift x 0.01%
Resolution

Shift x 0.01%
Accuracy

0.05%RG
Stability

0.01%/1min
Current (DC) Output/Measure
Shift

1mA/10mA/100mA/1A/5A/10A/25A
Adjusting range

0 ... 120%
Min Adjusting Unit

Shift x 0.01%
Resolution

Shift x 0.01%
Accuracy

0.05%RG
Stability

0.01%/1min
Max DC Output Load
Voltage 20VA, Current 25VA
Index measure reference condition
Environment temperature

22 1 C
Work temperature

0 C ... 40 C
Humidity range

?85 %
Work power supply range

220VAC 15%,50Hz
Weight

27KG
Dimensions

450?D?×180 (W)×380 (H) mm