The 16962A logic analysis module with 2.0 GT/s state speed and 2 GHz trigger
sequencer speed provides full capability to reliably trigger and capture all DDR
activity, including DDR3 1600. When used with a full suite of DDR probing
solutions (Interposer, BGA, SODIMM, mid-bus) and compliance/performance
analysis software, you obtain full test capability for system integration in the
memory industry.
Up to 125 ps (8 GHz), 400 M sample deep conventional timing analysis (2 GHz full-channel / 4 GHz half-channel / 8 GHz quarter-channel )
2 GHz transitional timing
State clock rates up to 2 GHz
Data rates up to 2 Gb/s (Double Data Rate - DDR) addresses all DDR speeds
Automated threshold/sample position setup for accurate measurements on high-speed buses
Simultaneous eye diagrams on all channels identify problems signals quickly
68-channels per module, combine up to 5 modules for 340 channels
Selectable memory depths: 4 M, 16 M, 32 M, 64 M, 100 M
Compatible with 90-pin logic analyzer probes. Probes are ordered separately. Agilent’s Probe Recommendations